In this case the highest end of the trusses is considered the ridge line and requires at least two braces over its length.
Mono pitch roof flashing detail.
Flashings soakers and saddles should be.
Fully annealed 0 55mm thick 0 7mm thick is suitable for gutters rolled lead sheet.
Figure 2 shows both.
Boiler stack detail.
These systems rely on overlapping elements roofing felts shingles tiles and flashing details to redirect the rainfall.
Best entrance design bundle.
Wall underlay self adhesive flashing tape cavity batten cladding cavity closure apron flashing to roof slope roofing 75 mm minimum 35 mm minimum 130 or 200 mm minimum depending on wind zone and roof pitch.
Balloon gutter outlet dwg.
Size up the job.
Bracing cad details for duo pitch roof.
Nz metal roof and wall cladding code of practice table of contents v 2 2 page 3 table of contents 1 1 0 table of contents 2 0p erformance 3 0 construction load 4 0 d esign 5 0f lashings 6 0p enetrations 7 0i nstallation 8 0 roof drainage 9 0 plastic roof lighting 10 0 pressed metal tiles 11 0 secret fixed cladding 12 0 insulated panels.
And the roof framing consists of trusses or a strutted roof either roof plane or roof space bracing is required in accordance with para graphs 10 3 2 and 10 3 3 for light and heavy roofs see figure 2.
Return to previous page.
Mono pitched roof construction is generally standalone roofs which imply that you don t need to attach them to any part of your roof.
Should be a minimum of 0 6mm thick.
Bracing cad details for mono pitch roof.
This kind of roofing is true to its name.
Common pitched roof systems rely on the force of gravity and the surface friction of the roofing materials to direct the flow of water downward and outward.
Back then local lumberyards stocked mono slope ridge flashing that looked like oversized drip edge.
This collection of 18 articles animations and videos identifies the critical roof flashing areas illustrates durable roof flashing details and shows how to flash roofs right in the real world.
Flashings gutter linings etc.
Mono meaning single and the slope is referred to as the pitch.
Architectural chimney flashing detail.
Apron flashing at roof wall junction horizontal flashing.
Bs en 12588.
Be a minimum of code 4 and soakers a minimum of code 3 sections should not exceed 1 5m in length.
Cad details document name pdf dwg download all cad construction details 37 1 mb 3 4 mb mc01 identification of roof areas 694 kb 167 kb mc01a single layer underlayment 678 kb 302 kb mc01b double layer underlayment 711 kb 322 kb mc02 vent pipe flashing 626 kb 349 kb mc03 valley.